Remote Connection Installation
Failure to remove power before installing the data logger may cause dam-
age to the data logger and/or station.
5. A small switch on the data logger near the cables controls the baud rate.
The default setting is 2400 baud. If you need to run at 1200 baud, change
the setting before connecting the data logger to the console.
6. Connect the short data logger cable to the cable jack marked “Weather-
Link” on the bottom of your weather station console.
7. Connect the blue Telephone Modem Adapter to the external modem.
The Telephone Modem Adapter (#7870) is required to use the data logger
with a modem. A standard DB25 connector with a gender changer will not
work.
8. Connect the long data logger cable to the Telephone Modem Adapter.
9. Turn the modem on.
10. Restore power to the weather station console by reattaching the power
adapter and listen for the console to emit beeps.
The console should beep three times. The third beep, which should occur
within 30 seconds, indicates that the data logger is operating correctly.
After hearing the three beeps, re-install the battery backup.
Typical Remote Installation for Original Weather Stations